Air-cooled product scheme features

1. Industrial-grade modular design, to facilitate the combination of different engineering requirements customization
2. Flexibility makes complex applications simple and highly integrated
3. Modular design, air-cooled system, full front-side maintenance, simple operation
4. High-power multi-unit inverter in parallel, easy expansion, support for fault-line unit to withdraw from redundancy, supporting faulty unit online redundancy exit
5. High-strength anti-vibration design
6. Engineering reliability design concept, strong overload capacity, excellent dynamic performance
7. With 100% unbalanced load capacity


Liquid-cooled product scheme features:

1. Liquid-cooled system, IP54 protection, C4/C5 strong anti-corrosion ability, meeting the port salt spray environment
2. High power density, small size, only covering the 1/2 area of equivalent power air-cooled system
3. Modular design, simple maintenance, high reliability
4. High-power multi-unit inverter in parallel, easy expansion, support for fault-line unit to withdraw from redundancy, supporting faulty unit online redundancy exit
5. Engineering reliability design concept, strong overload capacity, excellent dynamic performance
6. With 100% unbalanced load capacity


If you want to know some information about our company,pls check our website: www.hopewindelectric.com

Basic Rectifier Input Voltage 380V~480V  500V~690V
Input Frequency 47~63Hz
Fundamental Power Factor 0.95
PWM Rectifier Input Voltage 380V~480V  500V~690V
Input Frequency 47~63Hz
Power Factor 1
Inverter Output Output Voltage 400V  690V
Output Frequency 50/60Hz
Voltage Accuracy <1V
Output Voltage Waveform Distortion <5%
Full Load Transient Voltage Range <15%
Maximum Unbalanced Load Capacity 100%
Frequency Accuracy <0.1Hz
Overload Capacity Long time for 1.1 times the rated power, 10min for 1.2 times, 10s for 1.5 times
Voltage Fluctuation Recovery Time <1000ms
Environment Condition Temperature -15~40 no-derated, 40-55 derated using
Humidity 5%~95%, no condensation
Mechanical Data Anti Vibration Performance Comply with IEC 60721-3-3:2002 standard
Ingress Protection IP20 for air-cooled series, IP54 for liquid-cooled series
Security Level Comply with UL 508C-2004 standard
Cooling Method Air-cooled, liquid-cooled


NOTE:Voltage level04440V06690V


Model CapacitykVA Rated CurrentA Outline Dimension
Width * Height * Depth (mm)
UnThree-phase AC 400V
HP1000-10A100-04 100 176 1200*2200*600
HP1000-10A200-04 200 377 1200*2200*600
HP1000-10A500-04 500 802 1800*2200*600
HP1000-10A750-04 750 1283 2400*2200*600
HP1000-10A1000-04 1000 1604 3600*2200*600
HP1000-10A1500-04 1500 2566 4800*2200*600
UnThree-phase AC 690V
HP1000-10A100-06 100 102 1200*2200*600
HP1000-10A200-06 200 186 1200*2200*600
HP1000-10A500-06 500 465 1800*2200*600
HP1000-10A750-06 750 744 2400*2200*600
HP1000-10A1000-06 1000 1023 2400*2200*600
HP1000-10A1500-06 1500 1488 4800*2200*600
HP1000-10A2000-06 2000 2046 4800*2200*600
UnThree-phase AC 400V
HP1000-13A100-04 100 176 1600*2200*600
HP1000-13A200-04 200 377 1600*2200*600
HP1000-13A500-04 500 802 2200*2200*600
HP1000-13A750-04 750 1283 3000*2200*600
HP1000-13A1000-04 1000 1604 4400*2200*600
HP1000-13A1500-04 1500 2566 6000*2200*600
UnThree-phase AC 690V
HP1000-13A100-06 100 102 1600*2200*600
HP1000-13A200-06 200 186 1600*2200*600
HP1000-13A500-06 500 465 2400*2200*600
HP1000-13A750-06 750 744 3000*2200*600
HP1000-13A1000-06 1000 1023 3000*2200*600
HP1000-13A1500-06 1500 1488 6000*2200*600
HP1000-13A2000-06 2000 2046 6000*2200*600 




Related Product
  • Electronic stationary shore power source Medium and High Voltage Electronic stationary shore power source supply

    Medium and High Voltage Shore Power Supply Scheme features: 1. Liquid-cooled system, IP54 protection, C4/C5 strong anti-corrosion ability, meeting the port salt spray environment 2. Fewer devices, high reliability 3. High power density, small size, only covering the 1/2 area of equivalent power air-cooled system 4. High voltage, large power capacity 5. Excellent performance, strong overload capacity and excellent dynamic response 6. With 100% unbalanced load capacity 7. Air-cooled system protection level up to IP23 If you want to know some information about our company,pls check our website: www.hopewindelectric.com

  • LVRT domain grid simulation system Low-voltage Ride-through domain grid simulation system

    Low-voltage Ride-through Simulation System Features: 1. Low-voltage ride-through simulation system is able to faithfully simulate the various low-voltage faults of the power grid, including the grid voltage symmetrical dip and asymmetrical dip. 2. The dip curve is compliant with the regulations of the newest national standards, therein, the dip amplitude and dip duration of each stage can be set flexibly. As shown in the figure below: In the figure, the solid line is the contour of the work area of the turbine and the dashed line is the example of dip curve for actual test. If you want to know some information about our company,pls check our website: www.hopewindelectric.com

  • 1250kW/1562.5kW Centralized PV Grid-connected Inverter 1250kW/1562.5kW Centralized PV Grid-connected Inverter

    (DC1500V-without isolation transformer)

  • Wind Energy Converter Inspection assistant hopeScan Wind Energy Converter Inspection assistant

    hopeScanTM Patrol Assistant hopeScanTM patrol assistant, a monitoring software applicable to mobile intelligent devices, can access the converter through WIFI, for viewing information and obtaining fault data. The Assistant can also upload the data downloaded from the converters to the hopeCloudTM cloud server to create maintenance lists, access to the server for viewing the maintenance lists and participate in the converter maintenances. If you want to know some information about our company,pls check our website: www.hopewindelectric.com The working schematic diagram is as follows:

  • Plataforma de mantenimiento inteligente del convertidor de energía eólica Test-hopeCloud Plataforma de mantenimiento inteligente del convertidor de energía eólica

    Wind Power Converter Intelligent Maintenance Platform

  • C&D PV Grid-connected Inverter C&D PV Grid-connected Inverter

    (800kW/1000kW/1250kW)

  • Wind Converter Internet Monitoring System hopeView Wind Converter Internet Monitoring System

    hopeViewTM Converter Monitoring System hopeViewTM Converter Monitoring System, developed by Hopewind Electric with patented technology, can easily integrate all converters in the wind farm and quickly form a dedicated monitoring network. It can be installed in the Centre Control Room to implement real-time monitoring of the operation status,detailed parameters and fault alarm information of all converters in the wind farm. It can also enable the user to perform other practical functions such as observing parameter waveforms or trend curves online, and downloading event logs, fault logs, and fault records, etc. hopeViewTM Converter Monitoring System can help wind farm owners to improve the efficiency of operation and maintenance of the converters and wind turbines, even the whole wind power plant. Therefore it will eventually reduce the operation and maintenance cost of the wind farm.

Copyright © Shenzhen Hopewind Electric Co., Ltd. All Rights Reserved.dyyseo.com

online service

service

online service