Medium and High Voltage Shore Power Supply

Scheme features:

1. Liquid-cooled system, IP54 protection, C4/C5 strong anti-corrosion ability, meeting the port salt spray environment
2. Fewer devices, high reliability
3. High power density, small size, only covering the 1/2 area of equivalent power air-cooled system
4. High voltage, large power capacity
5. Excellent performance, strong overload capacity and excellent dynamic response
6. With 100% unbalanced load capacity
7. Air-cooled system protection level up to IP23


If you want to know some information about our company,pls check our website: www.hopewindelectric.com

Basic Rectifier Input Voltage 3300V 6600V 10000V
Input Frequency 47~63Hz
Fundamental Power Factor 0.95
PWM Rectifier Input Voltage 3300V 6600V 10000V
Input Frequency 47~63Hz
Power Factor 1
PWM Rectifier Output Voltage 3300V 6600V 10000V
Output Frequency 50/60Hz
Voltage Accuracy <1V
Output Voltage Waveform Distortion <5%
Full Load Transient Voltage Range <15%
Maximum Unbalanced Load Capacity 100%
Frequency Accuracy <0.1Hz
Overload Capacity Long time for 1.1 times the rated power, 10min for 1.2 times, 10s for 1.5 times
Voltage Fluctuation Recovery Time <1000ms
Environment Condition Temperature -15~40 no-derated, 40-55 derated using
Humidity 5%~95%, no condensation
Mechanical Data Anti Vibration Performance Comply with IEC 60721-3-3:2002 standard
Ingress Protection IP20 for air-cooled series, IP54 for liquid-cooled series
Security Level Comply with UL 508C-2004 standard
Cooling Method Air-cooled, liquid-cooled


NOTE:Voltage levelA33.3kV,B66.6kV,C111kV


Model CapacitykVA Rated CurrentA Outline Dimension
Width * Height * Depth (mm)
(including liquid-cooling machine, not including radiator)
UnThree-phase 3300V
HP1000-10A5000-A3 5000 875 5300*2200*1200
HP1000-10A6000-A3 6000 1050 5300*2200*1200
HP1000-10A7000-A3 7000 1225 5300*2200*1200
HP1000-10A8000-A3 8000 1400 5300*2200*1200
HP1000-10A9000-A3 9000 1575 5300*2200*1200
HP1000-10A10000-A3 10000 1700 5300*2200*1200
HP1000-10A12000-A3 12000 2040 5300*2200*1200
HP1000-13A5000-A3 5000 875 6300*2200*1200
HP1000-13A6000-A3 6000 1050 6300*2200*1200
HP1000-13A7000-A3 7000 1225 6300*2200*1200
HP1000-13A8000-A3 8000 1400 6300*2200*1200
HP1000-13A9000-A3 9000 1575 6300*2200*1200
HP1000-13A10000-A3 10000 1700 6300*2200*1200
HP1000-13A12000-A3 12000 2040 6300*2200*1200
UnThree-phase 6600V
HP1000-10A12000-B6 12000 1050 6500*2200*1200
HP1000-10A15000-B6 15000 1312 6500*2200*1200
HP1000-10A18000-B6 18000 1575 6500*2200*1200
HP1000-10A20000-B6 20000 1750 6500*2200*1200
HP1000-13A12000-B6 12000 1050 7500*2200*1200
HP1000-13A15000-B6 15000 1312 7500*2200*1200
HP1000-13A18000-B6 18000 1575 7500*2200*1200
HP1000-13A20000-B6 20000 1750 7500*2200*1200
UnThree-phase 11000V
HP1000-10A20000-C1 20000 1166 6500*2200*1200
HP1000-10A25000-C1 25000 1458 6500*2200*1200
HP1000-10A30000-C1 30000 1750 6500*2200*1200
HP1000-13A20000-C1 20000 1166 6500*2200*1200
HP1000-13A25000-C1 25000 1458 6500*2200*1200
HP1000-13A30000-C1 30000 1750 6500*2200*1200




Our company can also provide container-type shore power supply solutions, or customized according to customer needs, please contact Hopewind Electric if needed.







Related Product
  • Variable frequency bank power supply Low-voltage SVG Variable frequency bank power supply

    Low-voltage Shore Power Supply Air-cooled product scheme features: 1. Industrial-grade modular design, to facilitate the combination of different engineering requirements customization 2. Flexibility makes complex applications simple and highly integrated 3. Modular design, air-cooled system, full front-side maintenance, simple operation 4. High-power multi-unit inverter in parallel, easy expansion, support for fault-line unit to withdraw from redundancy, supporting faulty unit online redundancy exit 5. High-strength anti-vibration design 6. Engineering reliability design concept, strong overload capacity, excellent dynamic performance 7. With 100% unbalanced load capacity Liquid-cooled product scheme features: 1. Liquid-cooled system, IP54 protection, C4/C5 strong anti-corrosion ability, meeting the port salt spray environment 2. High power density, small size, only covering the 1/2 area of equivalent power air-cooled system 3. Modular design, simple maintenance, high reliability 4. High-power multi-unit inverter in parallel, easy expansion, support for fault-line unit to withdraw from redundancy, supporting faulty unit online redundancy exit 5. Engineering reliability design concept, strong overload capacity, excellent dynamic performance 6. With 100% unbalanced load capacity If you want to know some information about our company,pls check our website: www.hopewindelectric.com

  • Single-inverter Container Single-inverter Container

     (Single Inverter)

  • Wind Power Converter Intelligent Maintenance Platform Test-hopeCloud Wind Power Converter Intelligent Maintenance Platform

    Wind Power Converter Intelligent Maintenance Platform

  • vfd drive Oilfield vfd drive electric drive

    Oilfield Drive Drawing from years of experience and success in similar power electronics, Hopewind has launched a patented “All-in one energy feedback type drive". Designed particularly for oil pumping applications, this drive ranges from 15 to 90kW. Oil pumping is typically the most energy intensive operation of production, making it a worthy application of this specialized motor drive. Features: 1. Increase power factor over 40% without grid capacity expansion. 2. High starting torque at low frequency.        3. Continuous operation with as low as 320v input voltage. 4. Internal fitted DC reactor. Power factor 0.9, efficiency 99.6%. 5. Excellent tolerance of poor input power quality and harsh environmental conditions. 6. 30-50% energy savings on low yielding wells is achievable. 7. High protection grade enclosure (IP54) for use in application with heavy wind and dust. 8. Complete protection function: Intelligent monitoring for over voltage, over current, low voltage, over load, over heat etc. 9. Soft start/stop function: low mechanical impact. Low start current to extend the life of equipment. If you want to know some information about our company,pls check our website: www.hopewindelectric.com

  • LVRT domain grid simulation system Low-voltage Ride-through domain grid simulation system

    Low-voltage Ride-through Simulation System Features: 1. Low-voltage ride-through simulation system is able to faithfully simulate the various low-voltage faults of the power grid, including the grid voltage symmetrical dip and asymmetrical dip. 2. The dip curve is compliant with the regulations of the newest national standards, therein, the dip amplitude and dip duration of each stage can be set flexibly. As shown in the figure below: In the figure, the solid line is the contour of the work area of the turbine and the dashed line is the example of dip curve for actual test. If you want to know some information about our company,pls check our website: www.hopewindelectric.com

  • Solar Water Pump Inverter Solar Water Pump Inverter

    (200Vac~240Vac, 380Vac~480Vac)

  • C&D PV Grid-connected Inverter C&D PV Grid-connected Inverter

    (800kW/1000kW/1250kW)

Copyright © Shenzhen Hopewind Electric Co., Ltd. All Rights Reserved.dyyseo.com

online service

service

online service